Wood siding should be 4 or so from the ground whether that be soil or solid surface.
Conduit entering building from ground siding.
If the inside wiring is thinwall metal conduit then the junction box on the inside must be metal and the grounding wire must ground it.
Six inches would not be too far.
The wiring inside the shed must be either pvc conduit or thinwall metal conduit since it is exposed and subject to damage unless you are dry walling or paneling the insides of the wall.
Wiring buried inside rigid metal rmc or intermediate metal imc conduit must have at least 6 inches of earth cover.
Uf cable can be direct buried without conduit with a minimum of 24 inches of earth cover.
Water pipe which serves as the handle and screws into the bender head photo 5.
Step 3 attach the lb fitting to the pvc conduit using pvc glue.
When it is higher from the ground splashing water onto the wood is minimized.
Wiring in pvc conduit must have at least 18 inches of cover.
Service entrance conductors in a conduit coming off the bottom of a meter socket going into an lb and terminating in a loadcenter on an inside wall.
Single gang electrical boxes will work but if you have two or more conduit sections connecting to one box buy double gang.
I will usually seal off the conduit where it enters the building.
Make sure you have at least 1 inch of conduit exposed between the wall of your structure and the end of the conduit.
Electric conduit bender photo 5 is the only specialty tool you need to bend 10 ft.
The further the better.
Whatever size conduit you use don t fill it more than 40 percent with wires.
The male connectors on the ends of the pvc conduit take up quite a bit of room inside the box leaving little room for devices.
The normal code required clearance for exterior siding or stucco at a conrete patio or tile is 2.
Bending basics a 1 2 in.
Use outdoor silicone caulking around the conduit at the structure in order to hold the conduit into place and keep water from going inside your structure.
However most code inspectors in our area will allow as little as 1.
In this way the metal raceway acts in place of the grounding wire that is found in nm cable this is also the main reason why only metal boxes may be used with metal conduit.
Caulk the area with 100 percent silicon.
Shear loading can allow lager amounts of rh and water to enter wall openings.
The metal opening is 1 4 1 2 inch wider than the 2 5 3 inch conduit allowing weather to infiltrate area.
In some installations using metal conduit the raceway the conduit boxes and connectors serve as the ground for the circuit.
An underground feeder emerging from the ground into an lb entering the building and onward to the load.
You ll also need a 3 4 x 24 in.