Correctly sized trap discharge lines which slope in the direction of flow and are open ended or vented at a receiver will be non flooded and allow flash steam to pass unhindered above the condensate figure 14 3 3.
Condensate pump drain line size.
The inlet pipe should be on an angle where it enters the tank and should not interfere with the operation of the float valve that the pump uses.
Condensate pumps are typically sized at three times 3x normal condensing or evaporation rate.
An auxiliary drain pan with separate drain.
Imc 307 2 2 tells us that an a c condensate drain inside diameter should not be smaller than 3 4 and should not be smaller than the drain pan outlet diameter.
A minimum slope of 1 in 70 150 mm drop every 10 m is recommended.
3 4 is sufficient for up to 20 tons according to the imc unless the drain outlet size is larger than 3 4.
Suitable for use with condensate from air conditioning applications.
This pipe should be installed so that gravity will do the work when the pump is draining the system.
Furnished in 160 feet lengths with cut marks every 3 28 feet.
Attach the pump hose to the hose connector by pushing the tube fitting into the connector until it fits into place.
An auxiliary condensate drain pan at least 1 5 deep and at least 3 larger than the length width of the appliance beneath which it is placed using corrosion resistant material of adequate thickness 0 7mm galvanized metal or 1 6mm non metallic e g.
Use some sort of flexible tubing if possible as the drain pipe for the pump.
5 8 id uv resistant.
This large diameter drain line is typical for mini split installations.
Place the other end of the drain tube into a suitable drainage location like a drain sink or sump.
Vertically once the level of condensate in the tank reaches a specified level.
50 ft drain hose for ductless mini split air conditioner heat pump systems.
This product is designed to automatically pump condensate this product is designed to automatically pump condensate produced by high efficiency boilers and humidifiers up to 22 ft.
Do not use a longer length of tubing than the 16 ft provided.
Mini split condensate drain a unique drain line for mini split units.
Diversitech cp 22 series pumps beat the industry standard of 20 ft.
These guidelines are based upon design and operating experience.